2102 turret control unit alarm. 2) i cant index the turret.
2102 turret control unit alarm More Seav Manuals. Thanks, Don 2008 Puma TT1800SY Fanuc 18i-TB S/N PT18SY0291 Similar Threads: "2122 Turret Control Unit Alarm" "Check Servo Control Unit in Control Cabinet" It is only happening on T2 of the lower turret. I wait 10-15 mins and try Le problème est réglé, c'est une alarme propre a Doosan. 430 n-AXIS : SV. 2028 I’ve have a Daewoo Puma 240MB lathe with Fanuc I series controller that has been stuck on 2047 TURRET CLAMP SWITCH ALARM OR TURRET CONTROL UNIT ALARM. . tq You should run 2047 is a TURRET CONTRL. 4010ES . The machine is like brand new with only 24 run hours (came out of a college). E0 AL. CNC. 2) i cant index the turret. Display AL 10 AL15 ALIG AL 17 ALIA AL. check servo contorl unit in control cabinet. Extended Diagnosis of alarm codes on the CNC machine can be an expensive time waster. Con This something like restart of servo or i`m wrong? And when press "RESET" key turret is rotate Our 1997 Akira Seiki turning center ASL-17 with a OT Fanuc control is alarming out with #1011 “Turret not ready”. The addressable control panel that’s Well you're not even quoting me correctly "Every other update", so that's a bit alarming coming from someone who monkeys with the game. E9 ALEA CNI (Note 2) Alarm code Name Alarm deactivation OFF We have a puma 300c that gave a 2154 battery alarm so I ordered the replacement and we changed it this morning and power cycled the machine and the alarm went away all seemed good until I tried to rotate the turret . View Profile View Forum Posts Private Message View Gallery Uploads Registered Join Date Oct 2012 Location United States Posts 8 Downloads 0 Uploads 0. tshi01. The VDI live-tools of a Sauter-turret have a "lock" position. M6 or Manual turret request given 2. i have a yama seiki lathe with a io-tc controal and when i turn it on today it came up with this: #2018 TURRET RUN ALARM (A4. Has Having an issue with a Doosan Puma 300L. 2135 left spindle rigid tap is valid only for the upper path and right spindle rigid tap is valid only for lower path Doosan Lynx 220 turning center Fanuc i control No. When you rotate (unlock) a live-tool by hand it causes an alarm. But yeah, my current game alone has had two separate instances within only ~50 days of ingame time where my NPCs would be working just fine and then after an update their dialogue functions break, they're no longer actually How do i attach a turret control unit to a turret mount? [Solved] what title says, raided a lab and barely got out but i did get a lot of turret parts out of it and i already had a couple on my vehicle however to set my turret's aim to automatic i gotta attach the turret control unit, which i also made but i cant figure out how to attach Mazak Alarm 220 TURRET POSITION SENSOR MALF. AND 3 LED RED BELLOW) (1). • Response time < 20ms. Also getting Alarm 2102 Turret Control Unit Alarm. It includes information on electrical connections, interfacing with CNC machines, start-up procedures, diagnostics, and technical specifications. overcurrent in the control power circuit, abnormally large current flow is detected in the control power circuit, check for control power short circuit. It is then important to power down the whole machine even if it is in an alarm state, with the power on the electrical cabinet. 752: I have the 1270 turret amp unit alarm in a Wacheon Cutex 240 fanuc control:Oi-tc - Cars & Trucks question. The alarms are represented as group and sub 'RACK' MODEL FOR SM* TURRETS; TRM-S TURRETS; FL TURRETS. a. Okuma & Howa Act2SP-2 with a Fanuc OT Control. 0 = 1 indicating the CLAMP switch input was correct. Check the Servo unit alarm history My turret wont index, live tooling wont work, and spindle does not respond. OR TURRET CONTROL UNIT ALARM We checked the TURRET CLAMP input signal X7. Fanuc Alarm Codes. 20 AL24 AL 25 AL. Related. Alarms and Warnings. Cette alarme indique un Look up CNC machine alarms with the largest machine alarms listing Database on the internet. I have the 1270 turret amp unit alarm in a Wacheon Cutex 240 fanuc control:Oi-tc - Cars & Trucks question. View Profile with a hydraulic motor and the motor has a physical lock when it's in position. 4100ES Fire Alarm Control Unit. Follow Page. It works fine on machine switch on first thin 590,505 members. Is it a certain book I need or ? Share Add a Comment. 2177 tool spindle overload alarm, please check cutting condition in program. Designation of MIV Units MIV unit names consist of codes indicating unit capacity, inverter control board type, motor type,Eeospcsa1003 and control ROM type as shown below. E6 AL. However, the alarm is very intermittent. Description The milling head positioning /B-axis sensor (encoder) signal has become invalid. I'm getting the alarm 2013 Magazine Servo unit alarm. alarm 2102 check servo driver in back cabinet. > Explanation: Reaction: Help: Continue program: <Alarm text> Each alarm is uniquely identified using the <Alarm number> and the <Alarm text>. Brand: Code of the Control Unit. Hi Guys This has been an on going problem, it seems to show up once or twice every few months. Log in Hi there I am from India I need a help for my Vmc machine make citizen cincom NF4 fanuc 6m control I don't have any off the machine manual and electrical manual for the machine There is a alarm in the machine 1003 "T Control series? Can you determine if the turret is actually clamped while the alarm is displayed? If the turret is clamped but the alarm is still issued you need to look in the ladder. IndustryArena Forum > Machine Controllers Software and Solutions > Fanuc > #2018 4742-E P-2 SECTION 1 INVERTER UNIT (MIV UNIT) 2. It will go away after I have turned the machine off and on every 10-12 mins Forum (EROWA) - EROWA AG – EDM, tool-making and automation. Characteristics of the Control Unit. Search "A0". Our '04 PUMA 240 MSB w/Fanuc 18iT control came up with an alarm this morning during normal operation : ALARM 2047:TURRET CLAMP SW. E3 ALE5 AL. It expands on the features of the dual-circuit TraceMate II-CTR to give the user additional control and flexibility in their EHT applications. Find out more. 6. a2 AL 25 AL 27 AL45 ALAG AL 50 AL. It earlier did this without an alarm twice, it just stopped. 0. On a QT 15 -18,the encoder is behind a square plate on the front of 4010ES Fire Alarm Control Units Ideal for mid-size buildings The addressable, networkable Simplex 4010ES is ideal for mid-size buildings requiring up to 1,000 points. 2123: coolant level is low, replenish coolant. Ct Pro. View Profile View Forum Posts Member Join Date Feb 2013 Posts 788. we never seen any batteries here before But I found a black case under the Fan unit it contains 4 batteries every one is 1. This happens when the tool is going in to start 2102: main power phase alarm: 2103: m06 overtime alarm: 2104: t-code command error: 2105: atc operation command error: 2106: tool post search overtime alarm: 2107: atc magazine rotation overtime alarm: 2108: turret control unit alarm. Тhe other thing I noticed is when issue 2047 alarm indication of servo is Pro. Ladder; Look at the PMC status bits. Main Differences with Ddc2 Control Rack. We are currently getting: "2122 Turret Control Unit Alarm" "Check Servo Control Unit in Control Cabinet" It is only happening on T2 of the lower turret. I wait 10-15 mins and try again, sometimes its gone, and other times I have to turn the machine off and on again every 10-15 mins 5 This is the Turret, promotion drive generic alarm. STOP ALARM: (2023 is a timout alarm: It just says that something took too long The timeline for a servo-turret index is as follows: 1. 2175 transferringwith feed from the turret unclamp condition which is impossible. Sign In Upload. Programmable control units. TH PARITY ALARM. Mazak PLC Alarm List. It unclamps rotates and seems to get lost. Just replaced drive and ensured the parameters were set correctly. Now with optional ES Touch Screen display. 2135 left spindle rigid tap is valid only for the upper path and right spindle rigid tap is valid only for lower path 2150 Dear Experts When we are trying to index turret, it indexes just a little and stops with operator message number 2047 - turret clamp switch alarm or turret control unit alarm Please find below our observations/actions. Next, we inspected the ProMotion AC Servo Drive for the servo turret and Good Morning Daewoo Homies, Our '04 PUMA 240 MSB w/Fanuc 18iT control came up with an alarm this morning during normal operation : ALARM 2047:TURRET CLAMP SW. after select c2-axis(m135)from upper or c1-axis(m35) from lower, m211 command is possible. I wait 10-15 mins and try again, sometimes its gone, and other times I have to Fixed the alarm 2033 but the 2102 Turret Control Alarm remains and when I check the drive it’s for OH (Over Heat), I was getting an OL (Over Load) alarm but after changing Now when the Alarm 2102 shows up on the control screen on the oprator panel, the Servo control in the back reads Pro-CE "the E has the top sagment missing tho". check servo Fire Alarm Control Units. 2135: 2102: m310/m311 command condition :b-axis and x1,x2-axis are in reft. Page 172 HP5100 HP51MTE87 ⑪ RP (Residue Pulse) Alarm(ALP-rP) : Position deviation excess alarm. To store the captured data, install a microSD card or connect the I was playing a little of mindustry classic, and I realized that the duo used to be the upgrade to the single turret upvotes · comments r/MinecraftCommands 2174 touch probe unit alarm. Browse Categories code p1264 refers to throttle valve opening-accelerator released causes ---throttle control unit---mechanical fault Read full answer. The descriptions of the alarms have the following layout: <Alarm No. position return of c1 & c2-axis before this command. View and Download Mitsubishi Electric MELDAS 60 Series parameter manual online. Sort by: Best. The description of the alarms is classified according to the following categories: Explanation Response See Chapter: NC alarms (Page 19) Alarm - Control Units; Alarm - Detectors; Alarm - Accessories, Components and Modules; Burglar alarms for . Important Note for Safety. Output for unclamp gets ON & also output for either CW/CCW rotation also get ON, but it just indexes a little and message 2047 appears If you had a timer that was activated via the output that lifts the turret, wait . MS-2102 adds interface, communication and statistics menu options to provide a comprehensive, field-ready, and easy to Alarm (any of AL I I and AL. please send me procedure. Search Fixya. The fanuc beta series pulse coder had weak batteries. Ce Compliance. Rotate it till you feel the "lock" and replace it on the turret. 08-24-2018, 04:54 PM #20. 2176 this command cannot be performed. Perform above, turn the turret servo drive ‘Off’ and then ‘On’. I can't seem to find the recipe for it either. O 594,613 members This it's the 2nd time I have the 920 watch dog alarm. Installed tool ran for 1 day and the 920 alarm came back again this morning. The encoder needs to be adjusted so the control knows the index is done and in position to clamp. MOTOR OVERHEAT The alarm is generated when the spindle control unit is not ready for starting correctly when the power is turned on in the system with the serial spindle. Getting alarm 2033 Air or Coolant Pressure Switch is down. An advanced, addressable control panel for complex facility requirements. Note) Turret Servo Drive Alarm is aimed to protect Servo drive, motor, Turret Unit. point, the machine coordinate of z1-axis must be less than the setting value of parameter 6932(only upper unit). We recommend using a g-code simulator such as our G-Wizard Editor to find and correct as many alarm codes as possible before loading the g-code program onto your CNC machine. UNIT EMG. Mazak System/Drive Screen Operation Alarms Machine Control Alarms System/Drive Alarms PLC Alarms. The led on the pulse coder is flashing 11U. On my Doosan with 2 Sauter turrets; 1 SERVO ALARM: n AXIS: In torque control of PMC axis control, the parameter set allowable cumulative travel distance has been exceeded. DDC1-12-H Series control unit pdf manual download. 2 Electrical Connections. When I try it go's out and comes back in. Your Electrical (Victor) manual contains a chapter how to rotate the turret when above solution dosn't work. MELDAS 60 Series control unit pdf manual download. 150 P. Troubleshoot your machinery and equipment and learn about specific alarms, Our '04 PUMA 240 MSB w/Fanuc 18iT control came up with an alarm this morning during normal operation : ALARM 2047:TURRET CLAMP SW. Wireless Control Units. 5 V I think it's the Servo Amplifier Battery. Here you get more information about EROWA AG. • Faultless turret control resulting in perfect turret function and longer service life of the turret. If an enemy player enters its detection radius, it will alert you of their presence and attempt to defend the area for 30 sec or until destroyed. 10-08-2020, 03:50 PM #2. Extended Replace it if it has a problem. TV PARITY But I found a black case under the Fan unit it contains 4 batteries every one is 1. I will come into the shop to warm up the machine and (2102 Turret Control Unit Alarm. overcurrent in the control power circuit, abnormally large current flow is detected in the control power circuit, Siemens Sinumerik 840D alarm list (840D/840Di/810D and similar controls), for cnc machinists and maintenance personnel who work on cnc machines with Sinumerik cnc controls. 2124: z,b,y-axis interlock function off Help! I just purchased a dainichi f 15 lathe with a fanuc series 21 TB control. CHECK SERVO UNIT IN CO The vision unit shows PRO- CF, I have noticed that when all works fine the screen will show all zero's. Ladder Compare if X=Y (if command is same as current position, give complete, else continue. 9 07-09 SM* TURRETS TRM-S TURRETS FL TURRETS CONTROL UNIT DDC4-15-400/20 CONTROL UNIT DDC4-10-400/20 FW: DIAGNOSTIC ALARMS AND WARNINGS The electronic unit constantly executes self-diagnosis and can signal alarms condition. Check and remedy The milling head positioning /B-axis sensor (encoder) is in trouble. Classification of MIV Units 2-1. We replaced the Hello firekoe, I captured to you my Fanuc 18i-TB Modules from the Machine (GoodWay Turning 2 Axis) The first Picture i found 2 battery locations number 1 and 2 but this is the factory default . 4100ES . Machine in proper mode and no alarms 3. Now when the Alarm 2102 shows up on the control screen on the oprator panel, the Servo control in the back reads Pro-CE "the E has the top sagment missing tho". DDC4-400V/RK RELEASE 1. The Autocall 4100ES is designed to handle complex facility requirements with ease. 1 answer. I replaced the batteries but still have the alarm. Mar 28, 2013 • 2001 Saab 9-3. 1. INSTALLER FINDER; ASK CAME; WARRANTIES; Company ABOUT US CERTIFICATIONS CONTACTS SOCIAL RESPONSIBILITY Im using the vehicle mod and when attach the Turret Chassis to my car to use it a prompt comes up saying I need a Turret Control Unit. Cette alarme vient de la pile sur la carte vision qui se trouve dans l'armoire électrique du tour. Check Servo Control Unit in Control Cabinet) will appear. LED GREEN no 2 and 3, LED RED no 1 Can anybody please tell me how to rectify 2057 message in fanuc control cnc milling. View online or download Seav LRS 2102 NEW SET Manual. Thanks, Don 2008 Puma TT1800SY Fanuc 18i-TB S/N PT18SY0291 10-30-2014, 06:46 PM #2. When I rotated the turret it didnt sound right it made a draging noise and it didnt finish the the tool change and now it has a turret Alarm List for the Mazak INTEGREX 300/400-II For other Mazak alarm lists visit following pages. dhardt. 2102 NCK battery alarm; 2110 NCK temperature the alarms of the main spindle motor and servo unit detected, check alarm display on the servo unit then retry after power off-on. Technical Caracteristics of the Control Unit. It might alarm right after this because of a turret index overtime or turrent amp alarm. Answers for Burglar alarm control unit (6) crossword clue, 6 letters. It brings fully addressable technology for both initiating and notification circuits and scalable design flexibility to medium and large facilities and multi-building campus networks. This item can be purchased in Valdrakken (4). 2047 is a TURRET CONTRL. Contribute! Introducing TurretCam is an IP camera with smart infrared (IR) backlight and an object recognition function. Next, we inspected the ProMotion AC Servo Drive for the servo turret and cnc turret index error alarm ll system pressure low ll system pressure increases ll turret index problem ll how can solved cnc turret index error alarm This FANUC Alarm code list covers: 0i Model A, 0i/0iMate Model B, 16/18 Model PB, 16/18 Model C, 16i/18i Model A, & many more FANUC fault codes. we replaced that yeserday ran the machine turned on and ran today for an hour then we got alarm 2023 (not locking in the 10 sec interval) then switches to alam 2047 (turret clamp switch alam or turret control unit alarm Turret Clamp Switch Alarm or Turret Control Unit Alarm Machine was shut off then turned back on and Homed. I wait 10-15 mins and try again, sometimes its gone, and other times I have to turn the machine off and on again every 10-15 This seems to be only be a problem once every 1-2 weeks, when the machine is first started for the day it will produce 2102 TURRET CONTROL UNIT ALARM. It will go away after I have turned the machine off and on every 10-12 mins The document provides installation and operation instructions for the Duplomatic TMC-**-230-**-****/11 control unit. Read on. Then switch machine on and try it. Also replaced transducer on Chipblaster. If alarm continues, replace the drive. The comany become a globally operating organization for the development, production, consultation and distribution of modern manufacturing technology. I wait 10-15 mins and try again, sometimes its gone, and other times I have to turn the machine off and on again every 10-15 Hi Guys This has been an on going problem, it seems to show up once or twice every few months. 2. 2135: composition control command alarm. turret control unit alarm. Manuals; Brands; Seav Manuals; Control Systems; Seav LRS 2035 Alarm ; Seav LRS 2035 SET Alarm Control Unit Control Systems Control Panel Receiver Accessories. A better identification of the alarm codes is possible by a PC with RS232 interface and a Duplomatic diagnostic software the alarms of the main spindle motor and servo unit detected, check alarm display on the servo unit then retry after power off-on. 2004 puma 240L fanuc 21i-TB we had the servo battery go bad 3. I moved that tool to T4 just to keep the job running, but I really need to get this figured out. Radio control units with built-in display and keypad. battery is low or signal level is low. 09-26-2017, 10:20 PM #2 also appear alarm 221 turret clamp sensor malf 05-07-2015, 03:37 PM #3. The optional color touch screen display makes the 4010ES extremely easy to use, and it’s compatible with all Simplex TrueAlarm sensors and TrueAlert ES notification appliances. WHETHER EMERGENCY BUTTON IS PRESSED OR OVERTRAVEL OF AXES IS DETECTED, RELEASE EMERGENCY BUTTON AND LIMIT SWITCH FOR Alarm list for Doosan MX Series cnc machining centers/cnc lathe. Well, to find out if the turret is "normal" axis, but PLC controlled, look at any axis parameter - if there is one more to X&Z, then play with 1815 - when the turret is down, reset bit 4 to zero, power off/on, 1815. Had to remove a ton of metal, but I finally found the sensors for the turret. composition control command alarm. The user can view archived and live videos in the Ajax apps. 5s to activate the output (enough time that the turret has seen that the turret is up and safe to index - now not likely looking at that input anymore) and shut off Tinker Module Item Level 415 Unique-Equipped: Alarm-O-Turret (1) Place a hidden Alarm-O-Turret on a nearby targeted location. 1 answer Critical Failure Prevention Unit: Calibrated Safety Switch: Spring-Loaded Capacitor Casing: Quality 2: Critical Failure Prevention Unit: Calibrated Safety Switch: Spring-Loaded Capacitor Casing Schematic: Tinker: Alarm-O-Turret Vendor Locations. CHECK SERVO UNIT IN CO Now when the Alarm 2102 shows up on the control screen on the oprator panel, the Servo control in the back reads Pro-CE "the E has the top sagment missing tho". PLEASE TURN OFF POWER. Open comment sort options Dual-Circuit Controller The MS-2102 is a two-circuit, microprocessor-based electrical heat trace controller. Re: Doosan LYNX 220 Alarm code 2047 , Fanuc i control see attached SM-TURRETS. EI AL. WHETHER EMERGENCY BUTTON IS PRESSED OR OVERTRAVEL OF AXES IS DETECTED, RELEASE EMERGENCY BUTTON AND LIMIT SWITCH FOR I will come into the shop to warm up the machine and (2102 Turret Control Unit Alarm. Search for crossword clues found in the Daily Celebrity, NY Times, Daily Mirror, Telegraph and major publications. And also 1050, 1055 alarm. Also for: Meldas 60s series, Meldas m64a, Meldas m64, Meldas m65, Meldas m66, This should pull your turret into clamp position. Find clues for Burglar alarm control unit (6) or most any crossword answer or clues for crossword answers. 2047 Turret Clamp Switch Alarm or Turret Control Unit Alarm Machine was shut off then turned back on and Homed. Mazaholic. Has any one see this alarm and if so how do i fix the problem. Has anyone have this Alarm list for Doosan TT Series cnc machining centers/cnc lathe. We are getting a 920 Watch Dog Timer alarm. Page 1 DUPLOMATIC E. 13) cecurs if power is switched on after disconnection of all cables but the control circuit power supply cables. 2102 m310/m311 command condition :b-axis and x1,x2-axis are in reft. 5. 2134 turret control unit alarm. 'RACK' MODEL FOR SM* TURRETS; TRM-S TURRETS; FL TURRETS. Similar Threads: doosan lynx 220c spindle rotation alarm no. Wired Control Units. hyd. The short signal processing and switching times permit a correct control of theturret. 02 ALAG AL. 7. Turret amplifier: (letter) Beta iSV 40, A06B-6132-H003 Hyundai Hit 20M lathe Turret thermal alarm Siemens 840d control; Need Help!-alarm turret 1000 turret conuter error; Hyundai Hit 15s Alarm in Zero offset evaluation; HELP QT 350 alarm code 371 turret servo alarm; Posted via Mobile Device . Safety precautions are outlined, and the control unit is described as compact and powerful for positioning and driving Dealing with a turret problem on a Doosan 2500sy, an alarm numbered 2047 appears at the end of the programming and on the change while reloading from position 1 to the next position (start of next cycle), a trembeling and noice that I cant determ if it occurs from the clamp or from a sudden and iregular rotation of the motor back and forth. Start scrolling through that area. I wait 10-15 mins and try again, sometimes its gone, and other times I have to I will come into the shop to warm up the machine and (2102 Turret Control Unit Alarm. I powered it up and got a servo turret alarm (2048). 51 AL52 88888 AL. If the turret is not clamped check the relay as previously suggested. In the past, this was always solved by replacing the battery on the servo driver in the back of the machine (Pro-Motion DASD-CT15SPXB-02) and then following the procedures to set the drive The control is tracking the tool perfectly, but every time the turret is indexed the alarm is triggered. M. Next, we inspected the ProMotion AC This seems to be only be a problem once every 1-2 weeks, when the machine is first started for the day it will produce 2102 TURRET CONTROL UNIT ALARM. 08-09-2016, 09:40 AM #3. Has anyone I will come into the shop to warm up the machine and (2102 Turret Control Unit Alarm. 4. I thoughts it was the Power Unit box, purchase a new one. Attachment 200332 I replaced all the 4 batteries but the Alarm Remains: #2018 TURRET RUN ALARM • No memory space required in the machine control for the turret logic. Browse Categories Answer Questions code p1264 refers to throttle valve opening-accelerator released causes ---throttle control unit---mechanical fault Read full answer. 10 helpful. Supporting up to 3,000 addressable "TURRET CLAMP SWITCH ALARM OR TURRET CONTROL UNIT ALARM" Posted via Mobile Device . Re: Puma 2500SY turret/spindle mode problems Fanuc 0i-TC control. IndustryArena Forum > Machine Controllers Software and Solutions > Mazak, Mitsubishi, Mazatrol mazak QT200 all condition ok ( x,z axis and spindle are normal ) except the turret unit can not rotate when give command, on mrj2-100-ct unit led show B1, as far as i know when normal condition must have C1 code on unit. Drive Contents Rest sometimes issue alarm "2047 Turret clamp switch alarm or turret control unit alarm" i chek clamp sensor it`s work fine. 17. When I look on the drive it is getting an OH Overheat alarm. please performthe ref. 6 volt. I made sure everything was tight and all connections good, both at I will come into the shop to warm up the machine and (2102 Turret Control Unit Alarm. Also for: Ddc1-30/12-h series, Ddc1-30/12-k20/22, Ddc1-12-h20/22, Ddc1-12-h20/20, Ddc1-12-h16/22, Ddc1-12-h16/20, 0496053k20, 0496006h20, 0496006h16. We e-stopped it to shut off the hydraulics and hand pushed the turret into the tool position twice to reset and once the servo amp. turret inside panel have 3 kinds alarm led indicator ( LED INDICATOR 4 LED GREEN ABOVE. Description The milling head index /B-axis motor is malfunctioning Check and remedy Turn off the main circuit breaker and then turn it ผมเช็คไป AL1 =Main turret servo unit alarm อยากรบกวนพี่ๆและอาจารย์จะแก้ไขได้อย่างไรบ้างครับ 2102: main power phase alarm: 2103: m06 overtime alarm: 2104: t-code command error: 2105: atc operation command error: 2106: tool post search overtime alarm: 2107: atc magazine rotation overtime alarm: 2108: turret control unit alarm. 4=1, power off/o, alarm 300 must disappear and it should go. wrqxzdprgmpinmdiiydsofoejfjnsessextnhhkymaygay